Abstract:

The current scientific and engineering interest concerning the problems of preventing the emergency manifestations of drive synchronous motors, ensuring the ore grinding technological process has been justified. The analysis of the known works devoted to the abnormal operation modes of synchronous motors and possibilities of protection against them, has shown that their application is inexpedient for preventing the impermissible displays arising in the electrical drive synchronous motors ensuring the ore-grinding process. The main energy and technological factors affecting the technical condition of synchronous motors are evaluated. An algorithm for preventing the irregular operation modes of the electrical drive synchronous motor applied in the ore-grinding technological process has been developed and proposed for further application which gives an opportunity to provide smart solutions, ensuring the safe operation of the drive synchronous motor by a comprehensive consideration of the energy and technological factors.

Keywords: Synchronous motor, abnormal operating mode, electric drive, algorithm, energy factor, technological factor.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 508

References:


[1] Pavlyuk K., Bednarek S. Start-up and asynchronous modes of synchronous motors, М.: Energia, 272 p, 1971.
[2] Dadabaev Sh. T. “Analysis of starting modes of large vertical synchronous motors of pumping units,” Fourth International scientific-practical conference (Efficient and high-quality supply and use of electricity). Yekaterinburg, May 26-28, 2015.
[3] MARIAN HYLA “Impact of voltage dips on the operations of a high-power synchronous motor with a reactive power controller,” Silesian University of Technology: Mining - Informatics, Automation and Electrical Engineering. R. 54, №. 2- 5-13, pp.55-64, 2016.
[4] Hyla M. “Power supply unit for the excitation of a synchronous motor with a reactive power regulator,” Mining – Informatics, Automation and Electrical Engineering. №1(521), pp. 57-61, 2015.
[5] Kokoulin D. N., Shuin V. A. “Investigation of the algorithm of the relay protection blocking device during swings,” Bulletin of ISEU. Iss. 1, pp 1-5, 2012.
[6] Maliy A. P., Doni N. A., Shurupov A. A. “Calculation of the remote protection lock setting for swings based on the speed of resistance change,” Relay protection and automation. № 3, pp. 36-39, 2014.
[7] Mikhalev S. V. A system for maintaining the stability of synchronous motors of 6-10 kV. Diss. … Candidate of Techn. Sciences, /S. Pt., 2014.
[8] Joksimovic Gojko M., Penman Jim, The Detection of Inter-Turn Short Circuits in the Stator Windings of Operating Motors // IEEE Transactions on Industrial Electronics. Vol. 47, № 5, pp. 1078-1084, 2000.
[9] Suhk-Hoon Suh, Kwang-Joon Woo, “Serial Communication-Based Fault Diagnosis of a BLDC Motor Using Bayes Classifier,” International Journal of Control, Automation, and Systems. Vol. 1, № 3, pp. 308-314, 2003
[10] Selvaganesan N., Saraswathy Ramya R.” Fuzzy Fault Detection for Permanent Magnet Synchronous Generator,” ICTACT Journal on Soft Computing: Special Issue on Fuzzy in Industrial and Process Automation. Volume: 2, Issue: 1, pp. 224-232, July 2011.
[11] Hughes A. Electric Motors and Drives Fundamentals, Types and Applications, 410 p, 2006.
[12] Baghdasaryan M. K., Mnoyan T. N. “The Abnormal Operating Modes of Synchronous Electric Drive of an Ore Grinding Mill,” NPUA Bulletin, Collection of Scientific articles, Part 2, pp. 679-685, 2017.
[13] Baghdasaryan M.K., Mnoyan T.N., Sargsyan S.V. “A Method for Controlling the Abnormal Modes of the Synchronous Drive Motor of the Ore-Grinding Mill,” Eurasian Union of Scientists. № 4 (49), Part 1. P. 6-8, 2018.
[14] Baghdasaryan M. K., Mnoyan T. N. “Evaluation of the impact of the intra-mill load on the performance of the drive motor,” NPUA Bulletin. Electrical engineering, Power engineering. №2, pp. 22-33, 2017.