WASET
	@article{(Open Science Index):https://publications.waset.org/pdf/10010437,
	  title     = {Contribution to Improving the DFIG Control Using a Multi-Level Inverter},
	  author    = {Imane El Karaoui and  Mohammed Maaroufi and  Hamid Chaikhy},
	  country	= {},
	  institution	= {},
	  abstract     = {Doubly Fed Induction Generator (DFIG) is one of the most reliable wind generator. Major problem in wind power generation is to generate Sinusoidal signal with very low THD on variable speed caused by inverter two levels used. This paper presents a multi-level inverter whose objective is to reduce the THD and the dimensions of the output filter. This work proposes a three-level NPC-type inverter, the results simulation are presented demonstrating the efficiency of the proposed inverter.
},
	    journal   = {International Journal of Energy and Power Engineering},
	  volume    = {13},
	  number    = {6},
	  year      = {2019},
	  pages     = {385 - 388},
	  ee        = {https://publications.waset.org/pdf/10010437},
	  url   	= {https://publications.waset.org/vol/150},
	  bibsource = {https://publications.waset.org/},
	  issn  	= {eISSN: 1307-6892},
	  publisher = {World Academy of Science, Engineering and Technology},
	  index 	= {Open Science Index 150, 2019},
	}