Analysis of One-Way and Two-Way FSI Approaches to Characterise the Flow Regime and the Mechanical Behaviour during Closing Manoeuvring Operation of a Butterfly Valve
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32797
Analysis of One-Way and Two-Way FSI Approaches to Characterise the Flow Regime and the Mechanical Behaviour during Closing Manoeuvring Operation of a Butterfly Valve

Authors: M. Ezkurra, J. A. Esnaola, M. Martinez-Agirre, U. Etxeberria, U. Lertxundi, L. Colomo, M. Begiristain, I. Zurutuza

Abstract:

Butterfly valves are widely used industrial piping components as on-off and flow controlling devices. The main challenge in the design process of this type of valves is the correct dimensioning to ensure proper mechanical performance as well as to minimise flow losses that affect the efficiency of the system. Butterfly valves are typically dimensioned in a closed position based on mechanical approaches considering uniform hydrostatic pressure, whereas the flow losses are analysed by means of CFD simulations. The main limitation of these approaches is that they do not consider either the influence of the dynamics of the manoeuvring stage or coupled phenomena. Recent works have included the influence of the flow on the mechanical behaviour for different opening angles by means of one-way FSI approach. However, these works consider steady-state flow for the selected angles, not capturing the effect of the transient flow evolution during the manoeuvring stage. Two-way FSI modelling approach could allow overcoming such limitations providing more accurate results. Nevertheless, the use of this technique is limited due to the increase in the computational cost. In the present work, the applicability of FSI one-way and two-way approaches is evaluated for the analysis of butterfly valves, showing that not considering fluid-structure coupling involves not capturing the most critical situation for the valve disc.

Keywords: Butterfly valves, fluid-structure interaction, one-way approach, two-way approach.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1316365

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1537

References:


[1] M. G. Al-Azawy, A. Turan, and A. Revell, “Investigating the impact of non-Newtonian blood models within a heart pump,” International Journal for Numerical Methods in Biomedical Engineering, vol. 33, no. 1, 2017.
[2] L. Wang, X. Song, and Y. Park, “Dynamic analysis of three-dimensional flow in the opening process of a single-disc butterfly valve,” Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, vol. 224, no. 2, pp. 329–336, 2010.
[3] E. Krimmer, P. Baur, C. Lorenz, B. Hezel, and H. Hickl, “Butterfly valve with injection-molded shaft,” U.S. Patent No 6,901,942, 7 Jun. 2005.
[4] C. Huang and R. H. Kim, “Three-dimensional analysis of partially open butterfly valve flows,” Journal of fluids engineering, vol. 118, no. 3, pp. 562–568, 1996.
[5] G. Ibrahim, Z. Al-Otaibi, and H. M. Ahmed, “An Investigation of Butterfly Valve Flow Characteristics Using Numerical Technique,” Journal of Advanced Science and Engineering Research Vol, vol. 3, no. 2, pp. 151–166, 2013.
[6] X. Song, L. Wang, and Y. Park, “Analysis and optimization of a butterfly valve disc,” Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, vol. 223, no. 2, pp. 81–89, 2009.
[7] D. W. Roldán, M. de Souza and G. Francisco, “Risk-Based Analysis of LNG Carriers Loading and Unloading Operations,” in The Twenty-second International Offshore and Polar Engineering Conference, 2012.
[8] A. Göksenli and B. Eryürek, “Failure Analysis of Pipe System at a Hydroelectric Power Plant,” World Academy of Science, Engineering and Technology, International Journal of Mechanical, Aerospace, Industrial, Mechatronic and Manufacturing Engineering, vol. 9, no. 9, pp. 1643–1646, 2015.
[9] X. G. Song, L. Wang, and Y. C. Park, “Fluid and structural analysis of a large diameter butterfly valve,” Journal of Advanced Manufacturing Systems, vol. 8, no. 01, pp. 81–88, 2009.
[10] T. Sarpkaya, “Torque and cavitation characteristics of butterfly valves,” Journal of Applied Mechanics, vol. 28, no. 4, pp. 511–518, 1961.
[11] T. Kimura, T. Tanaka, K. Fujimoto, and K. Ogawa, “Hydrodynamic characteristics of a butterfly valve—prediction of pressure loss characteristics,” ISA transactions, vol. 34, no. 4, pp. 319–326, 1995.
[12] B. Goksel, J. Rencis, and M. Noori, “Finite element analyses of a butterfly valve assembly,” Journal of pressure vessel technology, vol. 111, p. 197, 1989.
[13] R. Kim and N. Wu, “Numerical simulation butterfly valve fluid flow,” in proceedings of the FLUENT User’s Group Meeting, 1992, pp. 296–313.
[14] Z. Leutwyler and C. Dalton, “A CFD study of the flow field, resultant force, and aerodynamic torque on a symmetric disk butterfly valve in a compressible fluid,” Journal of Pressure Vessel Technology, vol. 130, no. 2, p. 021302, 2008.
[15] R. Jaiman, H. Thomas, and F. Shakib, “Direct-Coupled Fluid-Structure Interaction for Automotive Applications,” SAE Technical Paper, 2012.
[16] A. El Hami and B. Radi, Fluid-Structure Interactions and Uncertainties: Ansys and Fluent Tools. John Wiley & Sons, 2017.
[17] O. C. Zienkiewicz, R. L. Taylor, and P. Nithiarasu, The Finite Element Method for Fluid Dynamics, 7th ed. Butterworth-Heinemann, 2014.