Effect of Hooked-End Steel Fibres Geometry on Pull-Out Behaviour of Ultra-High Performance Concrete
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32799
Effect of Hooked-End Steel Fibres Geometry on Pull-Out Behaviour of Ultra-High Performance Concrete

Authors: Sadoon Abdallah, Mizi Fan, Xiangming Zhou

Abstract:

In this study, a comprehensive approach has been adopted to examine in detail the effect of various hook geometries on bond-slip characteristics. Extensive single fibre pull-out tests on ultra-high performance matrix with three different W/B ratios and embedded lengths have been carried out. Test results showed that the mechanical deformation of fibre hook is the main mechanism governing the pull-out behaviour. Furthermore, the quantitative analyses have been completed to compare the hook design contribution of 3D, 4D and 5D fibres to assess overall pull-out behaviour. It was also revealed that there is a strong relationship between the magnitude of hook contribution and W/B ratio (i.e. matrix strength). Reducing the W/B ratio from 0.20 to 0.11 greatly optimizes the interfacial transition zone (ITZ) and enables better mobilization, straightening of the hook and results in bond-slip-hardening behaviour.

Keywords: Bond mechanisms, fibre-matrix interface, hook geometry, pullout behaviour and water to binder ratio.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1128020

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1621

References:


[1] A. Beglarigale, H. Yazıcı, Pull-out behavior of steel fiber embedded in flowable RPC and ordinary mortar, Constr. Build. Mater. 75 (2015) 255-265.
[2] J.M. Alwan, A.E. Naaman, P. Guerrero, Effect of mechanical clamping on the pull-out response of hooked steel fibers embedded in cementitious matrices, Concrete Science and Engineering. 1 (1999) 15-25.
[3] A.E. Naaman, H. Najm, Bond-slip mechanisms of steel fibers in concrete, ACI Mater. J. 88 (1991).
[4] T. Soetens, A. Van Gysel, S. Matthys, L. Taerwe, A semi-analytical model to predict the pull-out behaviour of inclined hooked-end steel fibres, Constr. Build. Mater. 43 (2013) 253-265.
[5] N. Banthia, J. Trottier, Concrete reinforced with deformed steel fibers, part I: bond-slip mechanisms, ACI Mater. J. 91 (1994).
[6] N. Banthia, A study of some factors affecting the fiber-matrix bond in steel fiber reinforced concrete, Canadian Journal of Civil Engineering. 17 (1990) 610-620.
[7] T. Abu-Lebdeh, S. Hamoush, W. Heard, B. Zornig, Effect of matrix strength on pullout behavior of steel fiber reinforced very-high strength concrete composites, Constr. Build. Mater. 25 (2011) 39-46.
[8] S. Abdallah, M. Fan, X. Zhou, S. Geyt, Anchorage Effects of Various Steel Fibre Architectures for Concrete Reinforcement, International Journal of Concrete Structures and Materials. (2016) 1-11.
[9] T. Rahmani, B. Kiani, M. Bakhshi, M. Shekarchizadeh, Application of different fibers to reduce plastic shrinkage cracking of concrete, (2012) 635-642.
[10] T. Rahmani, B. Kiani, M. Shekarchi, A. Safari, Statistical and experimental analysis on the behavior of fiber reinforced concretes subjected to drop weight test, Constr. Build. Mater. 37 (2012) 360-369.
[11] K. Wille, A.E. Naaman, Pullout behavior of high-strength steel fibers embedded in ultra-high-performance concrete, ACI Mater. J. 109 (2012).
[12] Y. Lee, S. Kang, J. Kim, Pullout behavior of inclined steel fiber in an ultra-high strength cementitious matrix, Constr. Build. Mater. 24 (2010) 2030-2041.
[13] I. Markovic, High-Performance Hybrid-Fibre Concrete: Development and Utilisation, IOS Press, 2006.
[14] F. Laranjeira de Oliveira, Design-Oriented Constitutive Model for Steel Fiber Reinforced Concrete, Universitat Politècnica de Catalunya, 2010.
[15] V.M. Cunha, Steel fibre reinforced self-compacting concrete (from micromechanics to composite behavior), (2010).
[16] E. Zīle, O. Zīle, Effect of the fiber geometry on the pullout response of mechanically deformed steel fibers, Cem. Concr. Res. 44 (2013) 18-24.
[17] D. joo Kim, Strain Rate Effect on High Performance Fiber Reinforced Cementitious Composites using Slip Hardening High Strength Deformed Steel Fibers, ProQuest, 2009.
[18] A.E. Naaman, Engineered steel fibers with optimal properties for reinforcement of cement composites, Journal of Advanced Concrete Technology. 1 (2003) 241-252.
[19] E. Baran, T. Akis, S. Yesilmen, Pull-out behavior of prestressing strands in steel fiber reinforced concrete, Constr. Build. Mater. 28 (2012) 362-371.
[20] E. Zīle, O. Zīle, Modelling the pullout of hooked steel fibers from cementitious matrix, (2013).
[21] S. Abdallah, M. Fan, D.W.A. Rees, Analysis and modelling of mechanical anchorage of 4D/5D hooked end steel fibres, Mater Des. 112 (2016) 539-552.
[22] G. Nammur Jr, A.E. Naaman, Bond stress model for fiber reinforced concrete based on bond stress-slip relationship, ACI Mater. J. 86 (1989).
[23] G. Chanvillard, Modeling the pullout of wire-drawn steel fibers, Cem. Concr. Res. 29 (1999) 1027-1037.
[24] G. Chanvillard, P. Aïtcin, Pull-out behavior of corrugated steel fibers: Qualitative and statistical analysis, Adv. Cem. Based Mater. 4 (1996) 28-41.