Tactile Sensory Digit Feedback for Cochlear Implant Electrode Insertion
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32794
Tactile Sensory Digit Feedback for Cochlear Implant Electrode Insertion

Authors: Yusuf Bulale, Mark Prince, Geoff Tansley, Peter Brett

Abstract:

Cochlear Implantation (CI) which became a routine procedure for the last decades is an electronic device that provides a sense of sound for patients who are severely and profoundly deaf. The optimal success of this implantation depends on the electrode technology and deep insertion techniques. However, this manual insertion procedure may cause mechanical trauma which can lead to severe destruction of the delicate intracochlear structure. Accordingly, future improvement of the cochlear electrode implant insertion needs reduction of the excessive force application during the cochlear implantation which causes tissue damage and trauma. This study is examined tool-tissue interaction of large prototype scale digit embedded with distributive tactile sensor based upon cochlear electrode and large prototype scale cochlea phantom for simulating the human cochlear which could lead to small scale digit requirements. The digit, distributive tactile sensors embedded with silicon-substrate was inserted into the cochlea phantom to measure any digit/phantom interaction and position of the digit in order to minimize tissue and trauma damage during the electrode cochlear insertion. The digit have provided tactile information from the digitphantom insertion interaction such as contact status, tip penetration, obstacles, relative shape and location, contact orientation and multiple contacts. The tests demonstrated that even devices of such a relative simple design with low cost have potential to improve cochlear implant surgery and other lumen mapping applications by providing tactile sensory feedback information and thus controlling the insertion through sensing and control of the tip of the implant during the insertion. In that approach, the surgeon could minimize the tissue damage and potential damage to the delicate structures within the cochlear caused by current manual electrode insertion of the cochlear implantation. This approach also can be applied to other minimally invasive surgery applications as well as diagnosis and path navigation procedures.

Keywords: Cochlear electrode insertion, distributive tactile sensory feedback information, flexible digit, minimally invasive surgery, tool/tissue interaction.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1110722

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2117

References:


[1] Kha H. N., B. K. Chen, G. M. Clark, R. Jones, “Stiffness Properties for Nucleus Standard Straight and Contour Electrode Arrays”, Medical Engineering & Physics 26 (8), pp. 677-685, Jan 2004.
[2] Kale S, Cervantes VM, Wu MR, Pisano DV, Sheth N, Olson ES, “A novel perfusion-based method for cochlear implant electrode insertion” Hearing research, 314 (1-2), pp. 33-41, May 2014.
[3] Lawrence T. Cohen, Saunders E., Clark G. M. “Psychophysics of a Prototype Perimodiolar Cochlear Implant Electrode Array”, Hearing research, 155 (1-2), pp. 63-81, 2001.
[4] Adunka Oliver, Jan Kiefer and Chapel Hill, “Impact of Electrode Insertion Depth on Intracochlear Trauma”, Otolaryngology-Head and Neck surgery 135, pp.374-382, 2006.
[5] J. Wang, M., Bhatti, P. T., Arcand, B. Y., Beach, K., Friedrich, C.. R., Wise, K. D., “A cochlear Electrode Array with Built-in Position Sensing”, International conference on Micro Electro Mechanical systems (MEMS), IEEE Xplore, 18th. 30 Jan.-3 Feb. 2005.
[6] Frank Tendik, S. Shankar Sastry, Ronald S. Fearing, and Michael Cohn, “Applications of Mechatronics in Minimally Invasive Surgery”, IEEE/ASME transactions on mechatronics, 3(1), p.34-42, 2006.
[7] Peter S. Roland, Wolfgang Gstottner, Oliver Adunka, “Method for hearing Preservation in cochlear implant surgery”, Operative Technology in Otolaryngology 16, pp.93-100, 2005.
[8] N. Donnelly, A. Bibas, D. Jiang, D. E. Bamiou, C. Santulli, G. Jeronimidis and A. Fitzgerald, “Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry”, The journal of laryngolgy and otology, 123, pp.723-729, 2009.
[9] Joseph B. Roberson, Jr, M. D., “Cochlear implant surgery: Minimally invasive technique”, Operative Techniques in Otolaryngology, 16, pp.74-77, 2005.
[10] J. H. M. Frinjns, J. J. Briaire, A. Zarowski, B. M. Verbist and J. Kuzma,“Concept and initial testing of a new, bassaly perimodiolar electrode design”, international congress series 1273 p.105-108, 2004.
[11] Paolo Dario, Maria Chiarra Carrozza, Maurilio Marcacci(2000). A novel mechatronic tool for computer-assisted arthroscopy. IEEE transaction on information technology in biomedicine. 4(1), pp. 15-29.
[12] S. Shimachi, Y. Fujiwara and Y. Hakozaki (2004). New sensing method of force acting on instrument for laparoscopic robot surgery, Computer Assisted Radiology and Surgery. Proceedings of the 18th International Congress and Exhibition International Congress Series, 1268, p.775-780.
[13] Stephen J. Rebscher Hetherington A, Bonham B, Wardrop P, Whinney D, Leake P. A., “Consideration for design of future cochlear implant electrode arrays: electrode array stiffness, size, and depth of insertion”, Journal of Rehabilitation Research & Development (JRRD),45( 4) pp.731-748, 2008.
[14] John K. Niparko, Cochlear implants: principles and practices, 2nd ed. Philadelphia, Lippincott Williams and Wilkins, 2009.
[15] Uwe Baumann, Andrea Nobbe, “The cochlear implant electrode-pitch function”, Hearing Research 213 (2006), pp34-42, 2006.
[16] Madhukar Vable, Mechanics of Materials, Oxford University press, 2nd edition, August 2012.
[17] Bernard Escude, Chris James, Olivier Deguine, Nadine Cochard, Elias Eter and Bernard Fraysse, The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes, Audiol Neurotol 2006;11(suppl 1), pp.27–33, 2006.
[18] Lawrence T. Cohen, Saunders E., Clark G. M., “Psychophysics of a prototype perimodiolar cochlear implant electrode array”, Hearing research, 155 (1-2), pp. 63-81, 2001.
[19] Andress Hussong, Thomas S. Rau, Tobias Ortmaier, Bodo Heinmann, Thomas Lenarz, Omid Majdani, “An automated insertion tool for cochlear implants: another step towards atraumatic cochlear implant surgery”, International Journal CARS, 5, pp.163-171, 2010.
[20] Graeme M. Clark, Review, “The multi-channel cochlear implant: Multidisciplinary development of electrical stimulation of the cochlea and the resulting clinical benefit”, Hearing research, 322, pp.4-13, 2015.
[21] Oliver Adunka, Marc H. Unkelbach, Martin G. Mack, Andreas Radeloff, Wolfgang Gstoettner, “Predicting Basal Cochlear Length for Electric- Acoustic Stimulation”, Arch Otolaryngol Head Neck Surg. 2005;131, pp.488-492, 2005.
[22] Michael J. Wittbrodt, Charles R. Steele, Sunil Puria, “Developing a Physical Model of the Human Cochlea Using Microfabrication Methods”, Audio Neurotol 2006;11:104–112, Jan 2006.