WASET
	%0 Journal Article
	%A Zasiah Tafheem and  Mahadee Hasan Shourav and  Zahidul Islam and  Saima Islam Tumpa
	%D 2015
	%J International Journal of Civil and Environmental Engineering
	%B World Academy of Science, Engineering and Technology
	%I Open Science Index 98, 2015
	%T Investigation of the Effect of Number of Story on Different Structural Components of RC Building
	%U https://publications.waset.org/pdf/10002819
	%V 98
	%X The paper aims at investigating the effect of number
of story on different structural components of reinforced concrete
building due to gravity and lateral loading. For the study, three
building models having same building plan of three, six and nine
stories are analyzed and designed using software package. All the
buildings are residential and are located in Dhaka city of Bangladesh.
Lateral load including wind and earthquake loading are applied to the
building along both longitudinal and transverse direction as per
Bangladesh National Building Code (BNBC, 2006). Equivalent static
force method is followed for the applied seismic loading. The present
study investigates as well as compares mainly total steel requirement
in different structural components for those buildings. It has been
found that total longitudinal steel requirement for beams at each floor
is 48.57% for three storied building, 61.36% for six storied building
when the total percentage is taken as 100% in case of nine storied
building. For an exterior column, the steel ratio is 2.1%, 3.06%,
4.55% for three, six and nine storied building respectively for the first
three floors. In addition, it has been noted that total weight of
longitudinal reinforcement of an interior column is 14.02 % for threestoried
building and 43.12% for six storied building when the total
reinforcement is considered 100% for nine storied building for the
first three floors.
	%P 217 - 221