	%T Seismic Behavior of Three-Dimensional Steel Buildings with Post-Tensioned Connections
	%U https://publications.waset.org/pdf/10000831
	%V 99
	%X The seismic responses of steel buildings with semirigid
post-tensioned connections (PC) are estimated and compared
with those of steel buildings with typical rigid (welded) connections
(RC). The comparison is made in terms of global and local response
parameters. The results indicate that the seismic responses in terms of
interstory shears, roof displacements, axial load and bending
moments are smaller for the buildings with PC connection. The
difference is larger for global than for local parameters, which in turn
varies from one column location to another. The reason for this
improved behavior is that the buildings with PC dissipate more
hysteretic energy than those with RC. In addition, unlike the case of
buildings with WC, for the PC structures the hysteretic energy is
mostly dissipated at the connections, which implies that structural
damage in beams and columns is not significant. According to these
results, steel buildings with PC are a viable option in high seismicity
areas because of their smaller response and self-centering connection
capacity as well as the fact that brittle failure is avoided.

	%P 302 - 309