Recurring as a Means of Partial Strength Recovery of Concrete Subjected to Elevated Temperatures
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 32799
Recurring as a Means of Partial Strength Recovery of Concrete Subjected to Elevated Temperatures

Authors: Shree Laxmi Prashant, Subhash C. Yaragal, K. S. Babu Narayan

Abstract:

Concrete is found to undergo degradation when subjected to elevated temperatures and loose substantial amount of its strength. The loss of strength in concrete is mainly attributed to decomposition of C-S-H and release of physically and chemically bound water, which begins when the exposure temperature exceeds 100°C. When such a concrete comes in contact with moisture, the cement paste is found rehydrate and considerable amount of strength lost is found to recover. This paper presents results of an experimental program carried out to investigate the effect of recuring on strength gain of OPC concrete specimens subjected to elevated temperatures from 200°C to 800°C, which were subjected to retention time of two hours and four hours at the designated temperature. Strength recoveries for concrete subjected to 7 designated elevated temperatures are compared. It is found that the efficacy of recuring as a measure of strength recovery reduces with increase in exposure temperature.

Keywords: Elevated Temperature, Recuring, Strength Recovery, Compressive strength.

Digital Object Identifier (DOI): doi.org/10.5281/zenodo.1099824

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2381

References:


[1] J P olliver, J C Maso, B Bourdette. “Interfacial Transition Zone in Concrete”. Advanced cement based materials vol.2, pp.30-38, 1995.
[2] Y. Xu, Y.L. Wong, C.S. Poon, M. Anson. “Influence of PFA on cracking of concrete and cement paste after exposure to high temperatures”, Cement and Concrete Research vol 33, pp. 2009–2016, 2003.
[3] Khoury G A, Majrona C E, Pasavento F Shrefler B A. “Modeling of heated concrete”. Magazine of Concrete Research, 54 vol 77 pp.101, 2002.
[4] Arioz O. “Effects of elevated temperatures on properties of concrete” Fire Safety Journal vol 42, pp. 516-522, 2007.
[5] B. Georgali, P. E. Tsakiridis. Microstructure of fire-damaged concrete. A case study Cement & Concrete Composites 27, 2005 255–259.
[6] D Campbell Allen,P M Desai. Influence of aggregate on behavior of concrete at elevated temperatures, Nuclear Engineering and Design, 6, August 1967, Pages 65-77.
[7] S C Chakrabarti, K N Sharma and Abha Mittal, ‘Residual strength in concrete after exposure to elevated temperature, The Indian Concrete Journal, Dec 1994 713-717.
[8] Chi-Sun Poon, Salman Azhar, Mike Anson, Yuk-Lung Wong, “Strength and durability recovery of fire-damaged concrete after post-firecuring”, Cement and Concrete Research, Volume 31, Issue 9, September 2001, Pages 1307-1318.
[9] C. Alonso, L. Fernandez. “Dehydration and rehydration processes of cement paste exposed to high temperature environments”, Journal of Materials Science vol 39 pp.3015 – 3024, 2004.
[10] Gabriel A. Khoury and Patrick J. E. Sullivan, ‘Research at Imperial College on the Effect of Elevated Temperatures on Concrete’, Fire Safety Journal, vol-13, pp.69 – 72, 1988.
[11] Yuzer, Nabi , Fevziye Akoz, Leyla Dokuzer O zturk, “Compressive strength–color change relation in mortars at high temperature”, Cement and Concrete Research vol- 34 pp.1803–1807, 2004.
[12] IS: 383-1970 "Specifications for coarse and fine aggregates from natural sources for concrete", Bureau of Indian Standards, New Delhi.